Artikelnummer | 0540-001 |
---|---|
EAN | 7331021008021 |
MSRP (verkoop advies prijs) | € 545,00 |
Voeding | Power in: 10–30 V DC or Power over Ethernet IEEE 802.3af/802.3at Type 1 Class 3 Power out & relay: 1x 12 V DC, max 500 mA 1x solid state relay 30 V DC, max 700 mA Power out lock: 2x 12 V DC, max 500 mA Total power budget if powered by DC: 1166 mA at 12 V for peripheral devices (locks, readers etc.) Total power budget if powered by PoE: 625 mA at 12 V for peripheral devices (locks, readers etc.) |
Maximum stroomverbruik (Watt) | 26 |
Afmetingen (cm) | 4.55 x 18 x 18 |
Garantie | 3 years |
Lezers | Up to 2 readers per controller (Wiegand, RS485 (OSDP)) with supported card formats. Integration with ASSA ABLOY Aperio® wireless lock technology. |
---|---|
Deuren (per controller) | 2 |
Login | Firmware version 1.50.0 or later: Up to 50 000 with third-party access management software depending on server capacity. Firmware versions earlier than 1.50.0: Up to 15 000 with third-party access management software depending on server capacity |
Gebeurtenis geschiedenis | 30.000 (FIFO) |
Toegang schema | Onbeperkt of software afhankelijk van derden |
I/O-functionaliteit | Reader I/O: DC output: 2x 12 V DC output max 300 mA; 2x 4 configurable inputs/outputs, (Digital input: 0 to max 40 V DC, Digital output: 0 to max 40 V DC, Open drain, max 100 mA) Reader data: RS485 full duplex, RS485 half duplex, Wiegand Auxiliary: 1x 3.3 V DC output, max 100 mA 2x configurable inputs/output (Digital input: 0 to max 40 V DC, Digital output: 0 to max 40 V DC, Open drain, max 100 mA) Door connectors: 2x 2 input for door monitors and REX (Digital input: 0 to max 40 V DC) Pre-configured for readers and door monitors, Input trigger, Output toggle/pulse |
---|
Beveiliging | Password protection, IP address filtering, HTTPS encryption, IEEE 802.1X network access control, Digest authentication, User access log |
---|---|
Ondersteunde protocollen (comptabiliteit) | IPv4, HTTP, HTTPS, TLSb, QoS layer 3 DiffServ, FTP, SMTP, Bonjour, UPnPTM, SNMPv1/v2c/v3 (MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS |
Applicatie programma interface (API) | Open API for software integration, including VAPIX®. AXIS Video Hosting System (AVHS) with One-Click Connection ONVIF Profile C and ONVIF Profile A |
---|
Sabotagedetectie | Removal of unit cover/tamper front Removal of unit from wall/tamper back, Reader tamper |
---|---|
Logboek | Configurable by time and topic, Alarm acknowledgement |
Acties voor evenementen | Notification via email, HTTP and TCP, External output port Status LED |
Detectie | Tamper detection, Power loss, Network lost, Configuration, Door, Event logger, Hardware, Input signal, Schedule, System, Time |
Behuizing | Plastic |
---|---|
Intern werkgeheugen | 256 MB RAM, 500 MB Flash |
Voeding | Power in: 10–30 V DC or Power over Ethernet IEEE 802.3af/802.3at Type 1 Class 3 Power out & relay: 1x 12 V DC, max 500 mA 1x solid state relay 30 V DC, max 700 mA Power out lock: 2x 12 V DC, max 500 mA Total power budget if powered by DC: 1166 mA at 12 V for peripheral devices (locks, readers etc.) Total power budget if powered by PoE: 625 mA at 12 V for peripheral devices (locks, readers etc.) |
Maximum stroomverbruik (Watt) | 26 |
Aansluitingen | RJ45 10BASE-T/100BASE-TX Terminal blocks: DC power, 10 Inputs/Outputs, RS485/Wiegand, Relay, Cable size for connectors: CSA: AWG 28–16, CUL/UL: AWG 30–14 |
Gebruikscondities (°C) | 0° to 50° |
Gebruikscondities luchtvochtigheid | 20–85% RH (non-condensing) |
Goedkeuringen | EN 55022 Class B, EN 50130-4, EN 61000-3-2, EN 61000-3-3, EN 55024, EN 61000-6-1, EN 61000-6-2, FCC Part 15 Subpart B Class B, ICES-003 Class B, C-tick AS/NZS CISPR22 Class B, VCCI Class B, IEC/EN/UL 60950-1, UL 294, UL 2043, EN 50581 |
Afmetingen (cm) | 4.55 x 18 x 18 |
Gewicht (kg) | 0.5000 |
Bijgevoegde accessoires | Connector kit, Cable ties, Installation Guide |
Garantie | 3 years |
AXIS A1001 Network Door Controller is an open, non-proprietary platform for access management. The controller is installed by each door and data is automatically synchronized between the controllers in the system. The controller supports most Wiegand and RS 485 OSDP readers. The unit comes with a built-in software for basic access management for up to 33 controllers as well as an open API to meet the requirements for larger and more advanced installations. The plenum rated controller is designed for wall or ceiling mount indoors and supports Power over Ethernet IEEE 802.3af Class 3. It is fitted with 14 configurable input/outputs and 5 power outputs for door accessories including fault/tamper detection and support for Uninterruptible Power Supply (UPS).
Innocam gebruikt cookies om het bezoek en winkelen bij innocam.nl voor u en ons makkelijker en veiliger te maken. Met deze cookies bewaren wij uw internetgedrag binnen onze website voor een volgend bezoek. Door verder gebruik te maken van onze website gaat u hiermee akkoord. Voor meer informatie, lees onze Privacy verklaring.